Manual Valves

Industrial Dampers

Dampers for isolating and controlling air and flue gas in boilers, ID / FD fan ducts and stacks. Built to duct size in carbon steel, Corten or stainless.

Standards

  • Built to duct size
  • AMCA 500-D (leakage)
Industrial Dampers

Available Products

TypeMaterialSizesPressure ClassEnd ConnectionStandard
Butterfly damperSS400, Corten, SS304DN150 - DN3000Duct design pressureFlanged to ductAMCA 500-D
Multi-louvre damperSS400, Corten, SS304Rectangular, to duct sizeDuct design pressureFlanged to ductAMCA 500-D
Guillotine damperSS400, Corten, SS310To duct sizeDuct design pressureFlanged to ductBuilt to duct size

Butterfly dampers for air and flue gas control, louvre dampers at fan inlets and outlets, guillotine dampers for positive isolation. Hand lever / quadrant, gear operator or actuator.

Pressure & Temperature Ratings

Dampers are designed for the duct's design pressure and gas temperature rather than an ASME valve class. Send us the duct size, gas temperature and required leakage rate.